Description
Updates the contents of the class dataset.
When requested, the input data will be validated first, and the class dataset will only be updated when the input data is correct.
When no validation is requested, the input data is written to the class dataset unconditionally, but this data cannot be written to the database (method DataSave will return an error). The data can only be saved as a draft instance.
Parameters
| il_Validate | input | logical | validate input data |
| BMfgInvoiceHistory | input | dataset | class dataset |
| oiReturnStatus | output | integer | error status |
program code (program/bmfginvoicehistory.p)
for each t_sih_hist:
if t_sih_hist.tc_Status = "D":U
then do:
run gipr_Delete_sidh_hist (input t_sih_hist.tc_Rowid).
end.
find first tFcRowidConvert where
tFcRowidConvert.tcFcOldRowid = t_sih_hist.tc_Rowid and
tFcRowidConvert.tlFcOk no-error.
if available tFcRowidConvert
then assign t_sih_hist.tc_Rowid = tFcRowidConvert.tcFcNewRowid.
end.
for each t_oih_hist where
not can-find (t_sih_hist where t_sih_hist.tc_Rowid = t_oih_hist.tc_Rowid):
create t_sih_hist.
raw-transfer t_oih_hist to t_sih_hist.
end.
for each t_sidh_hist:
find first tFcRowidConvert where
tFcRowidConvert.tcFcOldRowid = t_sidh_hist.tc_ParentRowid and
tFcRowidConvert.tlFcOk no-error.
if available tFcRowidConvert
then assign t_sidh_hist.tc_ParentRowid = tFcRowidConvert.tcFcNewRowid.
find first tFcRowidConvert where
tFcRowidConvert.tcFcOldRowid = t_sidh_hist.tc_Rowid and
tFcRowidConvert.tlFcOk no-error.
if available tFcRowidConvert
then assign t_sidh_hist.tc_Rowid = tFcRowidConvert.tcFcNewRowid.
end.
for each t_oidh_hist where
not can-find (t_sidh_hist where t_sidh_hist.tc_Rowid = t_oidh_hist.tc_Rowid) and
not can-find (t_sih_hist where t_sih_hist.tc_Rowid = t_oidh_hist.tc_ParentRowid and t_sih_hist.tc_Status = "D":U):
create t_sidh_hist.
raw-transfer t_oidh_hist to t_sidh_hist.
end.
if il_Validate
then do:
{ includes/bfcrun.i
&procedure = "CheckValidationExceptionList"
¶meters = "input true, output vl_validate" }
end.
if vl_Validate
then do:
{ includes/bfcrun.i
&procedure = "gipr_CompleteSTables" }
{ includes/bfcrun.i
&procedure = "ValidateComponent"
¶meters = "output oiReturnStatus" }
end.
if oiReturnStatus >= 0
then do:
{ includes/bfcrun.i
&procedure = "gipr_SetTables"
¶meters = "output viFcReturnSuper" }
if viFcReturnSuper <> 0
then assign oiReturnStatus = viFcReturnSuper.
end.
if il_Validate
and oiReturnStatus >= 0
then do:
{ includes/bfcrun.i
&procedure = "AdditionalUpdates"
¶meters = "output viFcReturnSuper" }
if viFcReturnSuper <> 0
then assign oiReturnStatus = viFcReturnSuper.
end.
if oiReturnStatus >= 0
then assign vlFcDataValidated = il_Validate.