Description
Updates the contents of the class dataset.
When requested, the input data will be validated first, and the class dataset will only be updated when the input data is correct.
When no validation is requested, the input data is written to the class dataset unconditionally, but this data cannot be written to the database (method DataSave will return an error). The data can only be saved as a draft instance.
Parameters
| il_Validate | input | logical | validate input data |
| BCompanyGroup | input | dataset | class dataset |
| oiReturnStatus | output | integer | error status |
program code (program/bcompanygroup.p)
for each t_sCyGroup:
if t_sCyGroup.tc_Status = "D":U
then do:
run gipr_Delete_sCyGroupCompany (input t_sCyGroup.tc_Rowid).
end.
find first tFcRowidConvert where
tFcRowidConvert.tcFcOldRowid = t_sCyGroup.tc_Rowid and
tFcRowidConvert.tlFcOk no-error.
if available tFcRowidConvert
then assign t_sCyGroup.tc_Rowid = tFcRowidConvert.tcFcNewRowid.
end.
for each t_oCyGroup where
not can-find (t_sCyGroup where t_sCyGroup.tc_Rowid = t_oCyGroup.tc_Rowid):
create t_sCyGroup.
raw-transfer t_oCyGroup to t_sCyGroup.
end.
for each t_sCyGroupCompany:
find first tFcRowidConvert where
tFcRowidConvert.tcFcOldRowid = t_sCyGroupCompany.tc_ParentRowid and
tFcRowidConvert.tlFcOk no-error.
if available tFcRowidConvert
then assign t_sCyGroupCompany.tc_ParentRowid = tFcRowidConvert.tcFcNewRowid.
find first tFcRowidConvert where
tFcRowidConvert.tcFcOldRowid = t_sCyGroupCompany.tc_Rowid and
tFcRowidConvert.tlFcOk no-error.
if available tFcRowidConvert
then assign t_sCyGroupCompany.tc_Rowid = tFcRowidConvert.tcFcNewRowid.
end.
for each t_oCyGroupCompany where
not can-find (t_sCyGroupCompany where t_sCyGroupCompany.tc_Rowid = t_oCyGroupCompany.tc_Rowid) and
not can-find (t_sCyGroup where t_sCyGroup.tc_Rowid = t_oCyGroupCompany.tc_ParentRowid and t_sCyGroup.tc_Status = "D":U):
create t_sCyGroupCompany.
raw-transfer t_oCyGroupCompany to t_sCyGroupCompany.
end.
if il_Validate
then do:
{ includes/bfcrun.i
&procedure = "CheckValidationExceptionList"
¶meters = "input true, output vl_validate" }
end.
if vl_Validate
then do:
{ includes/bfcrun.i
&procedure = "gipr_CompleteSTables" }
{ includes/bfcrun.i
&procedure = "ValidateComponent"
¶meters = "output oiReturnStatus" }
end.
if oiReturnStatus >= 0
then do:
{ includes/bfcrun.i
&procedure = "gipr_SetTables"
¶meters = "output viFcReturnSuper" }
if viFcReturnSuper <> 0
then assign oiReturnStatus = viFcReturnSuper.
end.
if il_Validate
and oiReturnStatus >= 0
then do:
{ includes/bfcrun.i
&procedure = "AdditionalUpdates"
¶meters = "output viFcReturnSuper" }
if viFcReturnSuper <> 0
then assign oiReturnStatus = viFcReturnSuper.
end.
if oiReturnStatus >= 0
then assign vlFcDataValidated = il_Validate.