project BLF > class BFieldSecurity > method ValidateComponent
Description
Write here all tests on database update (new / modify / delete) that cannot be coded with a validation mask.
The type of update can be found in tc_status (N/C/D).
If you find incorrect data, you must write an entry in tFcMessages (using SetMessage) and set the return status of this method to either +1 or -1.
Return status +1 = data will still be accepted.
Return status -1 = data will not be accepted.
This method is run from SetPublicTables, before transferring the received data into the class temp-tables.
Parameters
| oiReturnStatus | output | integer | |
Internal usage
unused
program code (program/bfieldsecurity.p)
/* ================================================================= */
/* Convert activity label into an ID */
/* ================================================================= */
for each t_sFieldSecurity where
t_sFieldSecurity.tc_Status = "N":U or
t_sFieldSecurity.tc_Status = "C":U :
if t_sFieldSecurity.tcBusActivityCode = ""
or t_sFieldSecurity.tcBusActivityCode = ?
or t_sFieldSecurity.tcBusComponentCode = ""
or t_sFieldSecurity.tcBusComponentCode = ?
then assign t_sFieldSecurity.BusActivity_ID = 0.
else do:
<Q-1 run BusActivityPrim (all) (Read) (NoCache) (input 0, (BusActivityID)
input t_sFieldSecurity.tcBusActivityCode, (BusActivityCode)
input t_sFieldSecurity.tcBusComponentCode, (BusComponentCode)
output dataset tqBusActivityPrim) in BBusinessComponent >
find first tqBusActivityPrim no-error.
if available tqBusActivityPrim
then assign t_sFieldSecurity.BusActivity_ID = tqBusActivityPrim.tiBusActivity_ID.
else do:
assign t_sFieldSecurity.BusActivity_ID = 0
oiReturnStatus = -1.
<M-2 run SetMessage (input #T-2'Invalid activity code.':40(466)T-2# (icMessage),
input '' (icArguments),
input 't_sFieldSecurity.tcBusActivityCode':U (icFieldName),
input t_sFieldSecurity.tcBusComponentCode + '/':U + t_sFieldSecurity.tcBusActivityCode (icFieldValue),
input 'E':U (icType),
input 3 (iiSeverity),
input t_sFieldSecurity.tc_Rowid (icRowid),
input 'BLF-107':U (icFcMsgNumber),
input '' (icFcExplanation),
input '' (icFcIdentification),
input '' (icFcContext),
output viFcReturnSuper (oiReturnStatus)) in BFieldSecurity>
end.
end.
end.
<ANCESTOR-CODE>